Test production and evaluation
Bonding test available. Please contact us.
|
Example of test production/evaluation test
- Automotive indutry :interior/exterior, electronic parts
- PV industry :PV module with curved surface, material evaluation
- Electrical and electronic industry:cover with curved surface, special resin, electronic parts
- Others :material evaluation
Example of use / vacuum bonding machine
※ swipe to view all ←←←
Use | Process | Products and application |
---|---|---|
|
|
|
Test models
■LM-100×100 |
|
|
|
Applicable size of heating plate |
1,000×1,000mm (Upper heating plate 800×800mm) |
---|---|
Height of the space inside chamber |
110mm *"Height of the space" does not indicate the maximum height of workpiece to laminate. |
Chamber |
opening and closing with column |
Vacuum reached |
133 Pa within 2 minutes *When the chamber is evacuated with no workpiece on the heating plate |
Vacuum gauge |
Bourdon gauge for upper and lower vacuum Upper and lower pressure sensor and Pirani gauge for lower vacuum |
Temperature control (4 zone) |
PID control (with auto-tuning function) Temperature range: 25 to 200℃ Maximum temperature gap: +/- 2℃ from set temperature |
Pressing control |
Around 0 to 1MPa (Atmospheric pressure 0.1Mpa +air press 0.6MPa + hydraulic press0.3MPa) |
Vacuum pump |
Rotary oil pump Busch Japan RA-0502C |
Heating plate |
Heater on upper plate (temperature range: 30 to 180℃) Cooling system (air/water cooling) |
■LM-50×50-S |
|
|
|
Applicable size of heating plate |
500×500mm |
---|---|
Height of the space inside chamber |
60mm *"Height of the space" does not indicate the maximum height of workpiece to laminate. |
Chamber |
opening and closing with column |
Vacuum reached |
133 Pa within 2 minutes *When the chamber is evacuated with no workpiece on the heating plate |
Vacuum gauge |
Bourdon gauge for upper and lower vacuum Upper and lower pressure sensor and Pirani gauge for lower vacuum |
Temperature control (1 zone) |
PID control (with auto-tuning function) Temperature range: 25 to 180℃ Maximum temperature gap: +/- 3℃ from set temperature |
Pressing control |
Around 0 to 0.5MPa (Atmospheric pressure 0.1Mpa + air pressing 0.4Mpa) |
Vacuum pump |
Rotary oil pump Leybold SV100B |
Heating plate |
equipped with supporting device pin |
Improved bonding accuracy with a high-presicion alignment device
Enables lamination of adhesive films with accuracy of +/- 50 μm or less making no air bubbles or wrinkles.
|
|
1. Set the workpiece fixed to a jig on the alignment table 2. Alignment with the vision system 3. The transfer lifts the jig by suction pads, and conveys the jig to the laminator |
Machinery Business
-