Solar Panel Inspection Machine
“Rakit” Multi-functional High-speed I-V Measurement System
“Rakit”
Rakit is a maintenance device to measure current and voltage characteristics string by string, to grasp solar system characteristics, abnormal data, etc.
The device comprising of I-V tracer, pyranometer, thermocouple, data logger, and "I-V data analyzer," the multi-functional analyzing software, provides accurate analysis report quickly. The I-V data analyzer is compatible with the following I-V tracers:
- Togami Electric Mfg.: SPST-B-1000
- EKO Instruments: MP-11
- Nippon Kernel System: Epsilon1000
4 min. 20 sec. subtitle: Japanese
Features of Rakit
Reduced power generation loss by quick measurement; faults detectable at a glance
Rakit measures up to 4 strings *1 at a time thanks to multiple probes (patented on multi-probe holder: JP5912156) of I-V tracer. Measurement time is shortened up to 2 hours per MW *2, thus power generation loss is reduced. Also, strings with defects can be detected immediately by comparing open voltage values.
*1 When string tracer made by Togami is used.
*2 Time required changes depending on actual installation conditions, environment, etc.
Adjustment according to irradiance and temperature (STC conversion) provides accurate data
Weather continuously changes during maintenance operation. Rakit provides accurate analysis results by automatically converting the measured data to values under standard test conditions (STC)*3 according to the irradiance and temperature stored in the data logger.
*3 Temperature: 25 degrees Celsius, irradiance: 1,000W/m²
I-V Data Analyzer: easy-to-use software enabling analysis anywhere
All you need is an internet environment: you can use the software anywhere. The cloud server enables remote data sharing among operators*4. User-friendly interface provides comfortable operation. |
Only internet environment |
Data sharing among operators |
Simple interface |
*4 One login per ID is allowed at a time.
Analysis report automatically issued in as little as 3 minutes
NPC original algorithm is used for analysis. From calculation, analysis to report issuance will be finished in only 3 minutes per MW. *5
3 decision criteria of resistance, I-V, and electricity are available for detecting abnormal values of strings. Abnormal Isc and Voc can be detected by comparing data simultaneously measured.
Criteria | Abnormal points | Possible causes |
---|---|---|
FF comparison | Increase/Decrease in serial/parallel resistance | Wiring peel-off, crack, PID*6, etc |
Comparison of values measured simultaneously | Decrease in Voc/Isc | Diode shortage, disconnection, discoloration of encapsulant, etc. |
Pmax comparison | Decrease in Pmax | All above |
Criteria |
---|
FF comparison |
Increase/Decrease in serial/parallel resistance |
Wiring peel-off, crack, PID*6, etc |
Abnormal points |
Comparison of values measured simultaneously |
Decrease in Voc/Isc |
Diode shortage, disconnection, discoloration of encapsulant, etc. |
Possible causes |
Pmax comparison |
Decrease in Pmax |
All above |
Examples of Analysis Screen
Pmax histogram after STC conversion (Shows total power output, power output difference of each string, etc.) |
---|
FF histogram (Shows power generation tendency. Criteria of strings changeable.) |
---|
I-V curves of all strings to be inspected and of good string |
---|
Respective I-V curve of string to be inspected (Shows I-V curves of abnormal strings one by one) |
---|
*5 Time required changes depending on actual installation conditions, environment, etc.
*6 Degradation phenomena often seen when plenty of series-connected solar panels are operated under high voltage.
Panel maintenance consulting services
Contact us for technical questions regarding
effective data recording, how to use Rakit, measured data, etc.
+81-89-946-6605( Matsuyama Factory)
Services
Solar Panel Reuse/Recycling
Solar Power Plant Inspection Service